Product name:Conductor ACCC Stockholm 2L

Item:Stockholm 2L

Details:

Code name Stockholm 2L
Mechanical Specifications    Metric   Imperial
Nominal Aluminum Cross-sectional Area* 463.3 mm2 914.3 kcmil
Nominal Diameter of Composite Core (CTC Part Number 200-006) 8.76 mm 0.345 in.
Nominal Cross-sectional Area of Core 60.3 mm2 0.093 in2
Overall Diameter of Conductor 26.40 mm 1.039 in.
Nominal Cross-sectional Area of the Conductor 523.6 mm2 0.812 in2
Ultimate Tensile Strength of Conductor1,2 156.2 kN 35.1 kips
Rated Strength of Core - 313 ksi (2158 MPa) 130.2 kN 29.3 kips
Core Nominal Mass per unit length 98 kg/km 66 lb/kft
Conductor Nominal Mass per unit length 1394.3 kg/km 937.1 lb/kft
Aluminum Nominal Mass per unit length** 1296.3 kg/km 871.2 lb/kft
Maximum Allowable Operating Temperature at Surface4 180 356
Coefficient of Linear Expansion Above Thermal Kneepoint 1.45E-06 / 8.06E-07 /
Coefficient of Linear Expansion Below Thermal Kneepoint 1.86E-05 / 1.03E-05 /
Final Modulus of Elasticity Above Thermal Kneepoint 116.0 GPa 16.8 Msi
Final Modulus of Elasticity Below Thermal Kneepoint 64.7 GPa 9.4 Msi
Electrical Specifications    Metric   Imperial
Nominal Resistivity of Aluminum at 20ºC, DC 63% IACS 0.0605 ohm/km 0.0974 ohm/mile
Temperature Coefficient of Resistance 0.00403   0.00403  
Frequency 50 Hz 60 Hz
AC Nominal Resistance at 25ºC 0.0625 ohm/km 0.1011 ohm/mile
AC Nominal Resistance at 75ºC 0.0746 ohm/km 0.1205 ohm/mile
AC Nominal Resistance at 180ºC 0.0999 ohm/km 0.1610 ohm/mile
AC Current Rating at Given Temperature3   1049 @ 100C & 50 Hz
  1576 @ 180C & 50 Hz
GMR (estimated) 0.01 m 0.0000 ft
Inductive Reactance 0.644 ohm/km 1.244 ohm/mile
Capacitive Reactance 0.180 Mohm-km 0.093 Mohm-mile











































  • ACCC® conductor is produced with 1350 O-tempered aluminum. The nominal H-19 Aluminum equivaelnt area is 476.9 sq. mm (941.2 kcmil).
  • ACCC® Conductors are required to exhibit lay lengths (ratios) that conform to ASTM B 857 or EN 50540.
1) Based on 96% of the annealed aluminum minimum tensile strength given in ASTM B 609 and EN 50540.
2) Strength at ambient temperature.
3) Conditions: 2 ft/s (0.61 m/s) wind, 0 ft (0 m) Elevation, 0.5 Emis. 0.5 absorp. 40°C Ambient  temperature, 96 W/sq. ft (1033 W/sq. m) sun radiation.
4) Maximum continuous operating temperature of ACCC® is 180°C and a maximum emergency temperature of 200°C (10,000 hours over the life of the conductor).
  • The information contained herein is offered in good faith. The actual configuration of a given size may vary between conductor manufacturers and may result in slight variations in some of the indicated values.

←[Previous:Stockholm 3L] [Next:Rome]→

Related Products :

Conductor ACCC Stockholm 3L

Stockholm 3L
Conductor ACCC Stockholm 3L

Conductor ACCC Mumbai

Mumbai
Conductor ACCC Mumbai

Conductor ACCC Glasgow

Glasgow
Conductor ACCC Glasgow

Conductor ACCC Berlin (HS Madrid)

Berlin (HS Madrid)
Conductor ACCC Berlin (HS Madrid)

Conductor ACCC Munich

Munich
Conductor ACCC Munich

Conductor ACCC Hamburg

Hamburg
Conductor ACCC Hamburg

Conductor ACCC Bordeaux

Bordeaux
Conductor ACCC Bordeaux

Conductor ACCC Oslo

Oslo
Conductor ACCC Oslo
Home   |    About Us   |    News   |    Products   |    Service   |    FAQ   |    Feedback   |    Contact Us   |    SiteMap
Copyright (c) 2014 Jiangsu Longyuan Electrical Equipment Co.,Ltd All Rights Reserved