Jiangsu Longyuan Electrical Equipment Co.,Ltd

Jiangsu Longyuan Electrical Equipment Co.,Ltd
Products

Conductor ACCC Reykjavik

Conductor ACCC Reykjavik

Product name:Conductor ACCC Reykjavik

Item:Reykjavik

Details:

code name Reykjavik
Mechanical Specifications    Metric   Imperial
Nominal Aluminum Cross-sectional Area* 223.1 mm2 440.3 kcmil
Nominal Diameter of Composite Core (CTC Part Number 200-004) 7.11 mm 0.280 in.
Nominal Cross-sectional Area of Core 39.7 mm2 0.062 in2
Overall Diameter of Conductor 18.82 mm 0.741 in.
Nominal Cross-sectional Area of the Conductor 262.8 mm2 0.407 in2
Ultimate Tensile Strength of Conductor1,2 98.3 kN 22.1 kips
Rated Strength of Core - 313 ksi (2158 MPa) 85.7 kN 19.3 kips
Core Nominal Mass per unit length 76 kg/km 51 lb/kft
Conductor Nominal Mass per unit length 693.6 kg/km 466.2 lb/kft
Aluminum Nominal Mass per unit length** 617.6 kg/km 415.1 lb/kft
Maximum Allowable Operating Temperature at Surface4 180 356
Coefficient of Linear Expansion Above Thermal Kneepoint 1.61E-06 / 8.94E-07 /
Coefficient of Linear Expansion Below Thermal Kneepoint 1.75E-05 / 9.75E-06 /
Final Modulus of Elasticity Above Thermal Kneepoint 112.3 GPa 16.3 Msi
Final Modulus of Elasticity Below Thermal Kneepoint 66.2 GPa 9.6 Msi
Electrical Specifications    Metric   Imperial
Nominal Resistivity of Aluminum at 20ºC, DC 63% IACS 0.1256 ohm/km 0.2021 ohm/mile
Temperature Coefficient of Resistance 0.00403   0.00403  
Frequency 50 Hz 60 Hz
AC Nominal Resistance at 25ºC 0.1285 ohm/km 0.2070 ohm/mile
AC Nominal Resistance at 75ºC 0.1537 ohm/km 0.2476 ohm/mile
AC Nominal Resistance at 180ºC 0.2067 ohm/km 0.3328 ohm/mile
AC Current Rating at Given Temperature3   665 @ 100C & 50 Hz
  986 @ 180C & 50 Hz
GMR (estimated) 0.01 m 0.0000 ft
Inductive Reactance 0.665 ohm/km 1.284 ohm/mile
Capacitive Reactance 0.199 Mohm-km 0.103 Mohm-mile











































  • ACCC® conductor is produced with 1350 O-tempered aluminum. The nominal H-19 Aluminum equivaelnt area is 229.7 sq. mm (453.2 kcmil).
  • ACCC® Conductors are required to exhibit lay lengths (ratios) that conform to ASTM B 857 or EN 50540.
1) Based on 96% of the annealed aluminum minimum tensile strength given in ASTM B 609 and EN 50540.
2) Strength at ambient temperature.
3) Conditions: 2 ft/s (0.61 m/s) wind, 0 ft (0 m) Elevation, 0.5 Emis. 0.5 absorp. 40°C Ambient  temperature, 96 W/sq. ft (1033 W/sq. m) sun radiation.
4) Maximum continuous operating temperature of ACCC® is 180°C and a maximum emergency temperature of 200°C (10,000 hours over the life of the conductor).
  • The information contained herein is offered in good faith. The actual configuration of a given size may vary between conductor manufacturers and may result in slight variations in some of the indicated values.

[Next:Prague]→

Related Products :

Conductor ACCC Prague

Prague
Conductor ACCC Prague

Conductor ACCC Oslo

Oslo
Conductor ACCC Oslo

Conductor ACCC Mumbai

Mumbai
Conductor ACCC Mumbai

Conductor ACCC Milan

Milan
Conductor ACCC Milan

Conductor ACCC  London

London
Conductor ACCC London

Conductor ACCC Kolkata

Kolkata
Conductor ACCC Kolkata

Conductor ACCC Glasgow

Glasgow
Conductor ACCC Glasgow

Conductor ACCC Dublin

Dublin
Conductor ACCC Dublin
Home   |    About Us   |    News   |    Products   |    Service   |    FAQ   |    Feedback   |    Contact Us   |    SiteMap