code name Monte Carlo
Mechanical Specifications    Metric   Imperial
Nominal Aluminum Cross-sectional Area* 228.5 mm2 450.9 kcmil
Nominal Diameter of Composite Core (CTC Part Number 200-011) 10.54 mm 0.415 in.
Nominal Cross-sectional Area of Core 87.3 mm2 0.135 in2
Overall Diameter of Conductor 20.78 mm 0.818 in.
Nominal Cross-sectional Area of the Conductor 315.8 mm2 0.489 in2
Ultimate Tensile Strength of Conductor1,2 201.2 kN 45.2 kips
Rated Strength of Core - 313 ksi (2158 MPa) 188.3 kN 42.3 kips
Core Nominal Mass per unit length 164 kg/km 110 lb/kft
Conductor Nominal Mass per unit length 798.7 kg/km 536.8 lb/kft
Aluminum Nominal Mass per unit length** 634.7 kg/km 426.5 lb/kft
Maximum Allowable Operating Temperature at Surface4 180 356
Coefficient of Linear Expansion Above Thermal Kneepoint 1.61E-06 / 8.94E-07 /
Coefficient of Linear Expansion Below Thermal Kneepoint 1.39E-05 / 7.74E-06 /
Final Modulus of Elasticity Above Thermal Kneepoint 112.3 GPa 16.3 Msi
Final Modulus of Elasticity Below Thermal Kneepoint 73.0 GPa 10.6 Msi
Electrical Specifications    Metric   Imperial
Nominal Resistivity of Aluminum at 20ºC, DC 63% IACS 0.1230 ohm/km 0.1979 ohm/mile
Temperature Coefficient of Resistance 0.00403   0.00403  
Frequency 50 Hz 60 Hz
AC Nominal Resistance at 25ºC 0.1257 ohm/km 0.2024 ohm/mile
AC Nominal Resistance at 75ºC 0.1504 ohm/km 0.2422 ohm/mile
AC Nominal Resistance at 180ºC 0.2024 ohm/km 0.3258 ohm/mile
AC Current Rating at Given Temperature3   691 @ 100C & 50 Hz
  1027 @ 180C & 50 Hz
GMR (estimated) 0.01 m 0.0000 ft
Inductive Reactance 0.656 ohm/km 1.267 ohm/mile
Capacitive Reactance 0.194 Mohm-km 0.100 Mohm-mile











































  • ACCC® conductor is produced with 1350 O-tempered aluminum. The nominal H-19 Aluminum equivaelnt area is 235.2 sq. mm (464.2 kcmil).
  • ACCC® Conductors are required to exhibit lay lengths (ratios) that conform to ASTM B 857 or EN 50540.
1) Based on 96% of the annealed aluminum minimum tensile strength given in ASTM B 609 and EN 50540.
2) Strength at ambient temperature.
3) Conditions: 2 ft/s (0.61 m/s) wind, 0 ft (0 m) Elevation, 0.5 Emis. 0.5 absorp. 40°C Ambient  temperature, 96 W/sq. ft (1033 W/sq. m) sun radiation.
4) Maximum continuous operating temperature of ACCC® is 180°C and a maximum emergency temperature of 200°C (10,000 hours over the life of the conductor).
  • The information contained herein is offered in good faith. The actual configuration of a given size may vary between conductor manufacturers and may result in slight variations in some of the indicated values.

←[Previous:Mumbai] [Next:Milan]→

Related Products :

Conductor ACCC Reykjavik

Reykjavik
Conductor ACCC Reykjavik

Conductor ACCC Munich

Munich
Conductor ACCC Munich

Conductor ACCC Madrid

Madrid
Conductor ACCC Madrid

Conductor ACCC Hamburg

Hamburg
Conductor ACCC Hamburg

Conductor ACCC Copenhagen

Copenhagen
Conductor ACCC Copenhagen

Conductor ACCC Bordeaux

Bordeaux
Conductor ACCC Bordeaux

Conductor ACCC Amsterdam

Amsterdam
Conductor ACCC Amsterdam

Conductor ACCC Rome

Rome
Conductor ACCC Rome
Home   |    About Us   |    News   |    Products   |    Service   |    FAQ   |    Feedback   |    Contact Us   |    SiteMap
Copyright (c) 2014 Jiangsu Longyuan Electrical Equipment Co.,Ltd All Rights Reserved