Product name:Conductor ACCC Madrid

Item:Madrid

Details:

Code name Madrid
Mechanical Specifications    Metric   Imperial
Nominal Aluminum Cross-sectional Area* 1013.1 mm2 1999.3 kcmil
Nominal Diameter of Composite Core (CTC Part Number 200-009) 9.78 mm 0.385 in.
Nominal Cross-sectional Area of Core 75.1 mm2 0.116 in2
Overall Diameter of Conductor 38.20 mm 1.504 in.
Nominal Cross-sectional Area of the Conductor 1088.2 mm2 1.687 in2
Ultimate Tensile Strength of Conductor1,2 219.1 kN 49.3 kips
Rated Strength of Core - 313 ksi (2158 MPa) 162.1 kN 36.4 kips
Core Nominal Mass per unit length 143 kg/km 96 lb/kft
Conductor Nominal Mass per unit length 2947.8 kg/km 1981.2 lb/kft
Aluminum Nominal Mass per unit length** 2804.8 kg/km 1885.1 lb/kft
Maximum Allowable Operating Temperature at Surface4 180 oC 356 oF
Coefficient of Linear Expansion Above Thermal Kneepoint 1.61E-06 /oC 8.94E-07 /oF
Coefficient of Linear Expansion Below Thermal Kneepoint 2.04E-05 /oC 1.13E-05 /oF
Final Modulus of Elasticity Above Thermal Kneepoint 112.3 GPa 16.3 Msi
Final Modulus of Elasticity Below Thermal Kneepoint 61.8 GPa 9.0 Msi
Electrical Specifications    Metric   Imperial
Nominal Resistivity of Aluminum at 20ºC, DC 63% IACS 0.0276 ohm/km 0.0444 ohm/mile
Temperature Coefficient of Resistance 0.00403   0.00403  
Frequency 50 Hz 60 Hz
AC Nominal Resistance at 25ºC 0.0302 ohm/km 0.0498 ohm/mile
AC Nominal Resistance at 75ºC 0.0354 ohm/km 0.0581 ohm/mile
AC Nominal Resistance at 180ºC 0.0464 ohm/km 0.0755 ohm/mile
AC Current Rating at Given Temperature3   1696 @ 100C & 50 Hz
  2602 @ 180C & 50 Hz
GMR (estimated) 0.02 m 0.0001 ft
Inductive Reactance 0.622 ohm/km 1.201 ohm/mile
Capacitive Reactance 0.159 Mohm-km 0.082 Mohm-mile











































  • ACCC® conductor is produced with 1350 O-tempered aluminum. The nominal H-19 Aluminum equivaelnt area is 1042.9 sq. mm (2058.1 kcmil).
  • ACCC® Conductors are required to exhibit lay lengths (ratios) that conform to ASTM B 857 or EN 50540.
1) Based on 96% of the annealed aluminum minimum tensile strength given in ASTM B 609 and EN 50540.
2) Strength at ambient temperature.
3) Conditions: 2 ft/s (0.61 m/s) wind, 0 ft (0 m) Elevation, 0.5 Emis. 0.5 absorp. 40°C Ambient  temperature, 96 W/sq. ft (1033 W/sq. m) sun radiation.
4) Maximum continuous operating temperature of ACCC® is 180°C and a maximum emergency temperature of 200°C (10,000 hours over the life of the conductor).
  • The information contained herein is offered in good faith. The actual configuration of a given size may vary between conductor manufacturers and may result in slight variations in some of the indicated values.

[Next:London]→

Related Products :

Conductor ACCC  Lisbon

Lisbon
Conductor ACCC Lisbon

Conductor ACCC Gdansk

Gdansk
Conductor ACCC Gdansk

Conductor ACCC Budapest

Budapest
Conductor ACCC Budapest

Conductor ACCC Athens

Athens
Conductor ACCC Athens

Conductor ACCC  London

London
Conductor ACCC London

Conductor ACCC Glasgow

Glasgow
Conductor ACCC Glasgow

Conductor ACCC Casablanca

Casablanca
Conductor ACCC Casablanca

Conductor ACCC Berlin (HS Madrid)

Berlin (HS Madrid)
Conductor ACCC Berlin (HS Madrid)
Home   |    About Us   |    News   |    Products   |    Service   |    FAQ   |    Feedback   |    Contact Us   |    SiteMap
Copyright (c) 2013 Jiangsu Longyuan Electrical Equipment Co.,Ltd All Rights Reserved