Jiangsu Longyuan Electrical Equipment Co.,Ltd

Jiangsu Longyuan Electrical Equipment Co.,Ltd
Products

Conductor ACCC Dublin

Conductor ACCC Dublin

Product name:Conductor ACCC Dublin

Item:Dublin

Details:

Code name Dublin
Mechanical Specifications    Metric   Imperial
Nominal Aluminum Cross-sectional Area* 524.5 mm2 1035.1 kcmil
Nominal Diameter of Composite Core (CTC Part Number 200-007) 9.53 mm 0.375 in.
Nominal Cross-sectional Area of Core 71.3 mm2 0.111 in2
Overall Diameter of Conductor 28.14 mm 1.108 in.
Nominal Cross-sectional Area of the Conductor 595.8 mm2 0.923 in2
Ultimate Tensile Strength of Conductor1,2 183.3 kN 41.2 kips
Rated Strength of Core - 313 ksi (2158 MPa) 153.8 kN 34.6 kips
Core Nominal Mass per unit length 132 kg/km 89 lb/kft
Conductor Nominal Mass per unit length 1583.0 kg/km 1063.9 lb/kft
Aluminum Nominal Mass per unit length** 1451.0 kg/km 975.2 lb/kft
Maximum Allowable Operating Temperature at Surface4 180 356
Coefficient of Linear Expansion Above Thermal Kneepoint 1.61E-06 / 8.94E-07 /
Coefficient of Linear Expansion Below Thermal Kneepoint 1.86E-05 / 1.03E-05 /
Final Modulus of Elasticity Above Thermal Kneepoint 112.3 GPa 16.3 Msi
Final Modulus of Elasticity Below Thermal Kneepoint 64.5 GPa 9.4 Msi
Electrical Specifications    Metric   Imperial
Nominal Resistivity of Aluminum at 20ºC, DC 63% IACS 0.0534 ohm/km 0.0859 ohm/mile
Temperature Coefficient of Resistance 0.00403   0.00403  
Frequency 50 Hz 60 Hz
AC Nominal Resistance at 25ºC 0.0553 ohm/km 0.0897 ohm/mile
AC Nominal Resistance at 75ºC 0.0660 ohm/km 0.1067 ohm/mile
AC Nominal Resistance at 180ºC 0.0883 ohm/km 0.1423 ohm/mile
AC Current Rating at Given Temperature3   1136 @ 100C & 50 Hz
  1711 @ 180C & 50 Hz
GMR (estimated) 0.01 m 0.0000 ft
Inductive Reactance 0.640 ohm/km 1.236 ohm/mile
Capacitive Reactance 0.176 Mohm-km 0.091 Mohm-mile











































  • ACCC® conductor is produced with 1350 O-tempered aluminum. The nominal H-19 Aluminum equivaelnt area is 539.9 sq. mm (1065.5 kcmil).
  • ACCC® Conductors are required to exhibit lay lengths (ratios) that conform to ASTM B 857 or EN 50540.
1) Based on 96% of the annealed aluminum minimum tensile strength given in ASTM B 609 and EN 50540.
2) Strength at ambient temperature.
3) Conditions: 2 ft/s (0.61 m/s) wind, 0 ft (0 m) Elevation, 0.5 Emis. 0.5 absorp. 40°C Ambient  temperature, 96 W/sq. ft (1033 W/sq. m) sun radiation.
4) Maximum continuous operating temperature of ACCC® is 180°C and a maximum emergency temperature of 200°C (10,000 hours over the life of the conductor).
  • The information contained herein is offered in good faith. The actual configuration of a given size may vary between conductor manufacturers and may result in slight variations in some of the indicated values.

[Next:Copenhagen]→

Related Products :

Conductor ACCC Copenhagen

Copenhagen
Conductor ACCC Copenhagen

Conductor ACCC Budapest

Budapest
Conductor ACCC Budapest

Conductor ACCC Bordeaux

Bordeaux
Conductor ACCC Bordeaux

Conductor ACCC Athens

Athens
Conductor ACCC Athens

Conductor ACCC Amsterdam

Amsterdam
Conductor ACCC Amsterdam

Conductor ACCC Casablanca

Casablanca
Conductor ACCC Casablanca

Conductor ACCC Brussels

Brussels
Conductor ACCC Brussels

Conductor ACCC Berlin (HS Madrid)

Berlin (HS Madrid)
Conductor ACCC Berlin (HS Madrid)
Home   |    About Us   |    News   |    Products   |    Service   |    FAQ   |    Feedback   |    Contact Us   |    SiteMap
Copyright (c) 2013 Jiangsu Longyuan Electrical Equipment Co.,Ltd All Rights Reserved